PeakFit General Features
PeakFit Requirements

 

APPLICATION GALLERY

PeakFit® is the automatic choice for Spectroscopy, Chromatography or Electrophoresis.

For Spectroscopy
 

PeakFit lets you accurately detect, separate and quantify hidden peaks that standard instrumentation would miss. PeakFit includes 18 different nonlinear spectral application line shapes, including the Gaussian, the Lorentzian, and the Voigt, and even a Gaussian plus Compton Edge model for fitting Gamma Ray peaks. As a product of the curve fitting process, PeakFit reports amplitude (intensity), area, center and width data for each peak. Overall area is determined by integrating the peak equations in the entire model. PeakFit can even deconvolve your spectral instrument response so that you can analyze your data without the smearing that your instrument introduces.

 

Click to View Larger Image
 
For Electrophoresis
 

PeakFit gives the electrophoresis user the ability to quickly and easily separate, locate and measure up to 100 peaks (bands), even if they overlap. With 82 nonlinear peak models to choose from, you're almost guaranteed to find the best equation for your data. The sophisticated array of baseline types lets you integrate only the significant portion of the bands in your data. The results of these measurements are then automatically recorded in a PeakFit-generated report, or they can be shown graphically. Combine PeakFit with our SigmaGel and a hand scanner, and you can often replace $10,000 electrophoresis instruments...with better results!

 

Click to View Larger Image
 
For Chromatography
 

PeakFit includes 8 different built-in equations for asymmetric peaks typically found in chromatography data including the Exponentially-Modified Gaussian, the Haarhoff-Van der Linde, the NLC, the Giddings and even a Half-Gaussian Modified Gaussian, an experimental model similar to the EMG, but used to describe intra-column originated asymmetry. The peak area is computed directly as a parameter within each of these functions, ensuring accuracy and enabling computation of confidence limits. PeakFit reports column efficiency, resolution, first moment (center of mass), second moment, center (mode), as well as peak width at base and half maximum, and asymmetry at base and 10 percent of maximum. PeakFit can even deconvolve your chromatographic detector response, so you can analyze your data without instrument induced asymmetry. PeakFit also supports AIA data file input.

 

Click to View Larger Image
 
For Signal Component Analysis
 

Even though PeakFit is widely used by chemists, biologists, etc., many Electrical Engineers have found PeakFit's statistical nonlinear fitting techniques extremely useful for separating overlapping signals.

 

Click to View Larger Image
 
A True Voigt Function
 

In Spectroscopy, instrument and Doppler broadening effects create a Gaussian line shape, while natural and collision broadening cause a Lorentzian line shape. The Voigt function is a convolution of both the Gaussian and Lorentzian functions. Most analysis packages that offer a Voigt function use an approximation with very limited precision. PeakFit actually uses a closed-form solution to precisely calculate the function analytically. PeakFit has four different Voigt functions, so you can fit the parameters you're most interested in, including the individual widths of both the Gaussian and Lorentzian components, and also the amplitude and area of the Voigt function. PeakFit's precise calculation of the Voigt function is crucial to the accuracy of your analysis.

 

Click to View Larger Image
 
Nonlinear Peak Separation and Analysis for Spectroscopy, Chromatography and Electrophoresis
 
PeakFit separates and analyzes nonlinear peak data better, more accurately and more conveniently than your lab instrument - here's why:
  • Advanced nonlinear curve fitting techniques separate overlapping peaks that standard instrumentation misses.
  • Peak finding and fitting is fully automated! PeakFit has three different procedures to accurately characterize normal and hidden peaks.
  • Graphically fit peaks yourself when you want to override PeakFit's automation.
  • Highly advanced data smoothing and manipulation techniques accurately process very noise data.
  • Revolutionary constant zero second derivates base-line fitting routine finds the best baseline. PeakFit also includes a non-parametric model for extremely complex backgrounds.
  • 82 built-in nonlinear equations (18 for spectroscopy and 8 for chromatography) and up to 15 user-defined functions fit virtually all data.
  • Fit up to 100 peaks at a time.
  • 32 - bit power and new Windows 95 interface plus, PeakFit is fully capable on Windows 3.1 and NT, With PeakFit, your accuracy will increase, and you'll find and fit your peaks faster than ever. Don't guess or rely on the accuracy of non-dedicated software made by hardware manufacturers. PeakFit far surpasses any other peak analysis package made!